Logistics robots are increasingly used for material transportation, warehouse operations, production-line logistics, sorting, and automated handling.
These robots depend on a reliable power system to operate drive motors, controllers, sensors, industrial computers, communication modules, lifting mechanisms, and safety systems.
A logistics robot battery is therefore more than a group of lithium cells. It is an integrated power system that may include battery cells, a Battery Management System (BMS), protection components, temperature sensors, busbars, connectors, wiring harnesses, and a custom enclosure.
For an OEM logistics robot manufacturer, battery selection should be based on the complete equipment requirements. Voltage and capacity are important, but current, operating cycle, charging method, communication protocol, dimensions, temperature, and mechanical installation also need to be evaluated.
This guide explains the engineering considerations involved in selecting and customizing lithium battery packs for logistics robots.

What Is a Logistics Robot Battery?
A logistics robot battery is a rechargeable battery pack designed to provide electrical power to robots used in warehouses, factories, distribution centers, and internal logistics systems.
Depending on the robot architecture, the battery can supply power to:
- Drive motors
- Lifting motors
- Motor controllers
- Industrial computers
- LiDAR
- Cameras
- Navigation sensors
- Safety sensors
- Wireless communication systems
- Control systems
- Displays and indicators
Different logistics robots have different power requirements.
For example, a mobile transport robot may primarily require power for traction, while a robot with lifting functions may have additional peak power requirements.
The battery configuration should therefore be developed according to the robot’s actual operating profile.
Lithium Battery Applications for Logistics Robots
Lithium battery packs can be designed for several types of automated logistics equipment.
Warehouse Robots
Warehouse robots can use lithium batteries for transportation, sorting, picking assistance, and internal material movement.
AGV
Automated Guided Vehicles use battery power for driving, control systems, sensors, and communication.
AMR
Autonomous Mobile Robots may require power for drive motors, navigation systems, LiDAR, cameras, computers, and wireless communication.
Automated Handling Robots
Robotic handling platforms may require additional power for lifting or material handling mechanisms.
Mobile Inspection Robots
Inspection robots may use battery power for movement, cameras, sensors, computers, and communication systems.
Each application requires a battery configuration based on its own electrical and mechanical specifications.
LiFePO4 Battery for Logistics Robots
LiFePO4, also known as lithium iron phosphate or LFP, is a lithium-ion battery chemistry that can be considered for industrial robotic applications.
LiFePO4 battery systems have characteristics including:
- Stable electrochemical behavior
- 열 안정성
- Rechargeable operation
- Suitability for repeated charge and discharge
- Compatibility with BMS protection systems
The battery configuration can be customized according to the required voltage and capacity.
For example, a 25.6V 100Ah LiFePO4 battery has a nominal energy of:
25.6V × 100Ah = 2,560Wh
This equals approximately:
2.56kWh
The actual usable energy depends on the battery operating window, load profile, temperature, BMS settings, and system efficiency.
Other lithium-ion chemistries may also be evaluated depending on the robot’s requirements.
How to Calculate Logistics Robot Battery Capacity
Battery capacity should be calculated from the robot’s energy requirements rather than selected only from the motor rating.
The basic formula is:
Battery Energy (Wh) = Voltage (V) × Capacity (Ah)
예를 들어
48V × 50Ah = 2,400Wh
The nominal battery energy is approximately 2.4kWh.
Estimated operating time can be calculated using:
Operating Time (h) = Available Energy (Wh) ÷ Average Power Consumption (W)
If the robot consumes an average of 600W:
2,400Wh ÷ 600W = 4 hours
This is a theoretical calculation.
Actual operating time can be affected by:
- Payload
- 이동 거리
- Driving speed
- 가속
- Braking
- 모터 효율
- Floor conditions
- Lifting operations
- Sensor consumption
- Computer consumption
- 주변 온도
- Battery operating window
- Charging strategy
For an OEM project, actual operating data should be used when available.
Average Power and Peak Power Requirements
A logistics robot does not necessarily consume the same amount of power throughout its operating cycle.
Power demand may increase during:
- 모터 시동
- 가속
- 회전
- Ramp operation
- Heavy-load transportation
- 리프팅
- Rapid movement
- System startup
The battery should therefore be evaluated using both average current 그리고 peak current.
Continuous Current
Continuous current refers to the current the battery needs to provide during normal operation.
Peak Current
Peak current refers to short-duration current requirements that may occur during motor startup, acceleration, lifting, or other high-load events.
The following components should be evaluated together:
- 배터리 셀
- BMS
- Fuse
- 버스바
- 케이블
- 커넥터
The BMS current rating should also be compatible with the robot’s operating requirements.
Smart BMS for Logistics Robot Battery Packs
The Battery Management System is an important component of a lithium battery pack.
A smart BMS can monitor and manage battery operating conditions.
Depending on the BMS design, monitoring functions can include:
- 개별 세포 전압
- 총 배터리 전압
- 충전 전류
- 방전 전류
- 배터리 온도
- 세포 온도
- SOC(충전 상태)
- 건강 상태 (SOH)
Protection functions may include:
- 과충전 방지
- 과방전 방지
- 과전류 보호
- 단락 보호
- 과열 보호
- Under-temperature protection
Cell balancing can also be implemented according to the battery configuration.
CAN Communication for Logistics Robot Batteries
Many industrial robots use communication between the battery and the main controller.
CAN communication can allow the BMS to transmit battery information such as:
- 배터리 전압
- 현재
- SOC
- 온도
- 충전 상태
- 고장 상태
- Alarm information
For an OEM logistics robot project, the communication protocol should be defined during the engineering stage.
The BMS needs to use communication parameters and data formats that are compatible with the robot controller.
If available, the customer can provide:
- CAN protocol
- CAN database file
- CAN ID information
- 데이터 형식
- 오류 코드
- SOC 요건
This information can be used when configuring or developing the smart BMS.
RS485 and UART Communication
Some logistics robots use RS485 or UART instead of CAN.
Possible battery communication interfaces include:
- CAN
- RS485
- UART
- Modbus RTU
The appropriate communication interface depends on the robot’s control architecture.
For customized battery development, communication requirements may include:
- Baud rate
- Address
- 데이터 형식
- Register information
- Communication commands
- 오류 정보
- SOC information
Communication testing should be completed during the prototype validation stage.
Battery Charging for Logistics Robots
The charger should be compatible with the battery chemistry and electrical configuration.
주요 충전 매개변수는 다음과 같습니다:
- 배터리 화학
- 공칭 전압
- 충전 전압
- 충전 전류
- 충전 프로필
- Charger type
- 커넥터
- BMS requirements
- 통신 요구 사항
For a custom battery project, the charger should be evaluated together with the battery.
A mismatch between the charger and battery specifications can affect charging performance and battery protection.
Charging Methods for Logistics Robots
Logistics robots can use different charging strategies depending on their operating schedule.
표준 충전
The robot returns to a designated charging area after completing an operating cycle.
This approach can be used when the robot has sufficient operating time between charging sessions.
기회 충전
The robot receives charging during idle periods.
Potential charging periods include:
- Breaks
- Waiting periods
- Shift changes
- Low-demand periods
- Automated docking
The battery should be designed according to the required charging current and charging frequency.
Automated Charging
AGVs and AMRs may automatically connect to charging stations.
The charging system may communicate with the battery BMS and robot controller.
Battery information may include:
- SOC
- 충전 상태
- 온도
- 고장 상태
- Charging permission
The battery, BMS, charger, and robot controller should be designed as a compatible system.
Custom Logistics Robot Battery Dimensions
Battery installation space is often defined by the robot’s mechanical structure.
A custom battery pack can be designed according to:
- 길이
- 너비
- 높이
- Battery compartment
- 장착 지점
- Connector location
- Cable outlet
- Handle
- Enclosure structure
For an OEM battery project, useful mechanical information includes:
- Battery compartment drawing
- 2D mechanical drawing
- 3D model
- Connector drawing
- Mounting specifications
This information can be used to develop a battery enclosure that fits the available installation space.
Battery Weight and Robot Design
Battery weight is another factor in logistics robot design.
The battery contributes to the total robot weight and may affect:
- Drive motor load
- 에너지 소비
- Payload
- Center of gravity
- Braking
- Mechanical structure
For this reason, battery capacity and battery weight should be considered together.
A battery with additional capacity also adds battery mass. The final configuration should therefore balance energy requirements with the robot’s mechanical and operational requirements.
Battery Enclosure Design
The battery enclosure protects the cells, BMS, wiring, and other electrical components.
Possible enclosure materials include:
- ABS
- PC
- 알루미늄
- 강철
- Engineering plastics
The enclosure can be designed to address:
- 기계적 보호
- 열 방출
- 먼지 방지
- 수자원 보호
- Connector placement
- 케이블 배선
- Mounting
- 유지보수 접근 권한
The appropriate enclosure structure depends on the robot’s working environment and mechanical requirements.
환경 요건
Logistics robots can operate in different environments, including:
- 창고
- 물류 센터
- 생산 시설
- Production lines
- Cold storage
- Loading areas
Potential environmental factors include:
- 온도
- 습도
- 먼지
- Water
- 진동
- Mechanical impact
The battery design should define the required operating and charging temperature range.
For applications requiring protection against dust or water, an appropriate IP-rated enclosure can be considered.
The selected IP rating should be verified through applicable testing.
Safety Design for Logistics Robot Lithium Batteries
Battery safety involves multiple components and design stages.
세포 선택
Battery cells should be evaluated according to:
- 용량
- 전압
- 정류 전류
- 피크 전류
- 내부 저항
- Cycle requirements
- 작동 온도
- Manufacturer specifications
BMS 보호
BMS parameters should be configured according to:
- 셀 구성
- 배터리 전압
- 현재
- 온도
- 충전 요건
- Discharging requirements
Electrical Protection
A battery pack may include:
- Fuse
- Busbar
- 보호 회로
- 단열
- 온도 센서
- Rated connectors
- Appropriate cables
Thermal Design
Thermal considerations may include:
- 세포 화학
- 현재
- Operating cycle
- 주변 온도
- 첨부 파일
- 열 방출
기계적 보호
The battery enclosure and mounting structure should be designed according to the vibration and mechanical conditions expected during robot operation.
Logistics Robot Battery Testing
Battery testing should be defined according to the battery design, equipment requirements, and applicable standards.
용량 테스트
Capacity testing can verify battery performance under defined charging and discharging conditions.
BMS Testing
BMS testing may evaluate:
- 과충전 방지
- 과방전 방지
- 과전류 보호
- 단락 보호
- 온도 보호
- 셀 밸런싱
통신 테스트
For smart battery systems, testing may include:
- CAN 통신
- RS485 통신
- UART 통신
- SOC data
- Fault reporting
- 충전 상태
온도 시험
Depending on the application, testing may include:
- High-temperature operation
- 저온 작동
- Charging at defined temperatures
- 온도 모니터링
Mechanical Testing
Depending on the equipment requirements:
- 진동 테스트
- Impact testing
- Connector testing
- Mounting testing
- Enclosure inspection
Testing requirements should be defined based on the actual battery design and intended application.
Logistics Robot Battery Certifications and Compliance
Battery certification and compliance requirements depend on:
- 배터리 화학
- Battery configuration
- Product application
- Destination market
- Transportation method
- Applicable regulations
For lithium batteries transported internationally, UN 38.3 is an important transportation testing requirement.
Depending on the product and target market, additional requirements may include:
- CE
- IEC 표준
- UL 표준
- RoHS
- EMC requirements
- Regional battery regulations
For products placed on the European market, applicable requirements under EU 배터리 규정(EU) 2023/1542 should also be evaluated.
Certification requirements should be considered during the battery development stage rather than only after the battery has entered production.
Custom Logistics Robot Battery Development Process
A structured development process helps connect the battery with the robot’s electrical and mechanical systems.
Step 1: Equipment Requirement Analysis
수집:
- Robot model
- 공칭 전압
- 모터 출력
- Average current
- 피크 전류
- 운영 시간
- 충전 요건
- 배터리 치수
- 통신 요구 사항
Step 2: Operating Profile
Evaluate:
- 매일 운영 시간
- Operating cycles
- Payload
- 이동 거리
- Driving speed
- 가속
- Lifting frequency
- 충전 빈도
Step 3: Cell Selection
Evaluate:
- 세포 화학
- 용량
- 전압
- Current capability
- 내부 저항
- 치수
- Temperature specifications
Step 4: Battery Configuration
Determine:
- Series connection
- Parallel connection
- 공칭 전압
- 용량
- 에너지
- Current capability
Step 5: BMS Development
Define:
- Protection parameters
- Current rating
- 온도 센서
- SOC
- SOH
- CAN
- RS485
- UART
Step 6: Mechanical Design
Develop:
- 배터리 케이스
- 장착 구조
- 커넥터
- Cable
- 배선 하네스
- 배터리 치수
Step 7: Prototype Production
The prototype can be evaluated for:
- Physical installation
- Electrical compatibility
- Charging
- 커뮤니케이션
- 운영 시간
- 온도
- Mechanical integration
Step 8: Testing
Testing can be performed according to:
- 배터리 사양
- Equipment requirements
- Target market
- Applicable standards
Step 9: Validation and Production
After prototype validation, the battery design can move into production with defined quality control and inspection procedures.
OEM and ODM Logistics Robot Battery Pack
OEM and ODM battery development allows the battery to be designed around the customer’s equipment.
Electrical Customization
- 전압
- 용량
- 셀 구성
- 방전 전류
- 배터리 화학
BMS Customization
- Protection parameters
- SOC
- SOH
- CAN
- RS485
- UART
Mechanical Customization
- 배터리 치수
- 첨부 파일
- Mounting
- 커넥터
- Cable
- 배선 하네스
Charging Customization
- 충전 전압
- 충전 전류
- Charger compatibility
- Charging communication
Product Customization
Depending on the project:
- Battery label
- Product identification
- Packaging
- Technical documentation
What Information Is Needed for a Custom Logistics Robot Battery?
For accurate battery engineering, the following information is useful:
| 요구사항 | 예시 |
|---|---|
| Robot type | AGV / AMR / Logistics Robot |
| 배터리 화학 | LiFePO4 / Li-ion |
| 공칭 전압 | 24V / 36V / 48V / 51.2V |
| 용량 | 아 |
| Average current | A |
| 피크 전류 | A |
| 운영 시간 | Hours |
| 충전 시간 | Hours |
| 충전기 | Model / Specification |
| 커뮤니케이션 | CAN / RS485 / UART |
| 배터리 치수 | L × W × H |
| 커넥터 | Model / Specification |
| 작동 온도 | °C |
| IP requirement | Application dependent |
| Target market | EU / US / Japan / Other |
| Quantity | Prototype / Batch Production |
Additional information can include:
- Equipment datasheet
- Original battery specifications
- Charger datasheet
- Motor datasheet
- Controller datasheet
- Battery compartment drawing
- Connector drawing
- 통신 프로토콜
- 3D model
How to Choose a Logistics Robot Battery Manufacturer
Selecting a battery manufacturer involves more than comparing battery prices.
For an OEM project, manufacturers can be evaluated based on engineering, production, testing, documentation, and compliance capabilities.
Battery Engineering Capability
The supplier should be able to evaluate:
- 세포 선택
- Battery configuration
- BMS
- Current requirements
- 커뮤니케이션
- Charging
- Mechanical integration
제조 역량
Relevant production processes may include:
- 세포 등급 분류
- 세포 매칭
- 용접
- PACK assembly
- BMS 설치
- Aging
- 전기 시험
- 최종 검사
Testing Capability
Testing may include:
- 용량 테스트
- BMS 테스트
- 통신 테스트
- 온도 시험
- 진동 테스트
- Waterproof testing when required
Documentation
For OEM battery projects, useful documents can include:
- Battery specification
- Cell datasheet
- BMS specification
- Test reports
- Certification documents
- Charging specifications
- 통신 프로토콜
Technical claims should be supported by appropriate documentation.
Engineering Considerations When Designing a Logistics Robot Battery
From a battery engineering perspective, capacity is only one part of the battery design.
A logistics robot battery should be evaluated through several parameters.
1. Energy
배터리 에너지는 다음 공식을 사용하여 추정할 수 있습니다:
에너지(Wh) = 전압(V) × 용량(Ah)
2. Current
The battery should support the required continuous and peak current.
3. Operating Cycle
The battery requirement depends on how often the robot:
- Drives
- Stops
- Accelerates
- Turns
- Lifts
- Carries loads
- Returns to the charging station
4. Charging Strategy
The battery should be designed according to:
- Standard charging
- 기회 충전
- Automated charging
5. Communication
When the robot controller requires battery information, the BMS may need:
- CAN
- RS485
- UART
6. Installation
The battery needs to fit the robot’s:
- Battery compartment
- 장착 지점
- Connector location
- 케이블 배선
- Weight limitations
7. Environment
The battery should be evaluated according to:
- 온도
- 습도
- 먼지
- Water
- 진동
This engineering approach helps define the battery as part of the robot’s complete power system.
동관 이잔 전자 기술 유한 회사 소개
동관 이잔 전자 기술 유한 공사(동관 이잔 전자 기술 유한 공사) is a lithium battery PACK manufacturer providing customized battery solutions for industrial equipment and robotics applications.
The company’s battery development process can cover:
Requirement Analysis → Cell Selection → Battery Configuration → BMS Design → Mechanical Design → Prototype → Testing → Certification Evaluation → Production
Battery applications include:
- 물류 로봇
- 창고용 로봇
- AGV
- AMR
- 검사 로봇
- 산업용 로봇
- 전동 지게차
- Walkie stackers
- 팔레트 트럭
- Other mobile industrial equipment
Depending on project requirements, battery packs can integrate:
- LiFePO4 셀
- 리튬 이온 전지
- 스마트 BMS
- CAN 통신
- RS485 통신
- UART 통신
- 온도 센서
- Custom connectors
- Custom wiring harnesses
- Custom enclosures
The final battery configuration is determined according to the customer’s equipment specifications, operating conditions, charging requirements, communication system, mechanical structure, and target market.
Why Customize a Battery for a Logistics Robot?
A standard battery may not match the electrical and mechanical requirements of a specific logistics robot.
Custom battery development can address several areas.
전기 사양
- 전압
- 용량
- 현재
- 에너지
Communication Requirements
- CAN
- RS485
- UART
- Other supported protocols
기계적 요구 사항
- 치수
- Mounting
- 커넥터 위치
- 케이블 길이
- 첨부 파일
Charging Requirements
- 충전 전압
- 충전 전류
- Charger compatibility
- Charging strategy
환경 요건
- 작동 온도
- 습도
- 먼지
- 물 노출
- 진동
Compliance Requirements
- Transportation testing
- Market-specific regulations
- Applicable product standards
For OEM robotics manufacturers, these requirements can be defined during the robot development stage.
Logistics Robot Battery Quality Control
Quality control should cover the battery from incoming cells to finished PACK.
A typical process may include:
Cell Inspection
Cells can be inspected for:
- 전압
- 내부 저항
- 용량
- Physical condition
Cell Matching
Cells can be grouped according to defined electrical parameters.
PACK Assembly
Battery assembly may include:
- 세포 배열
- 버스바 연결
- 용접
- BMS 설치
- Wiring
- 단열
- Enclosure assembly
기능 테스트
The finished battery can be tested for:
- 전압
- 용량
- Charging
- Discharging
- BMS 기능
- 커뮤니케이션
Aging
Battery aging can be used to identify potential electrical or assembly issues before shipment.
최종 검사
Final inspection can include:
- 모양
- 치수
- 커넥터
- 전압
- 커뮤니케이션
- 보호 기능
- Labeling
The specific inspection procedure depends on the battery design and production requirements.
Logistics Robot Battery Selection Checklist
Before ordering a lithium battery for a logistics robot, confirm the following.
전기
☐ Nominal voltage
☐ Capacity
☐ Energy
☐ Continuous current
☐ Peak current
☐ Cell chemistry
BMS
☐ Overcharge protection
☐ Over-discharge protection
☐ Over-current protection
☐ Temperature protection
☐ SOC
☐ SOH
☐ Cell balancing
커뮤니케이션
☐ CAN
☐ RS485
☐ UART
☐ Communication protocol
☐ Data format
Charging
☐ Charging voltage
☐ Charging current
☐ Charger compatibility
☐ Charging method
☐ Automated charging requirements
Mechanical
☐ Battery dimensions
☐ Weight
☐ Mounting points
☐ Connector position
☐ Cable length
☐ Enclosure
Environment
☐ Operating temperature
☐ Charging temperature
☐ Humidity
☐ Dust
☐ Water exposure
☐ Vibration
Compliance
☐ UN 38.3
☐ Applicable IEC standards
☐ Applicable UL standards
☐ CE requirements
☐ RoHS
☐ EU Battery Regulation requirements where applicable
자주 묻는 질문
What type of battery is used in logistics robots?
Lithium-ion batteries, including LiFePO4 battery systems, can be used for logistics robots. The appropriate battery chemistry depends on the robot’s voltage, capacity, current, operating cycle, temperature, and installation requirements.
Can I customize a lithium battery for my logistics robot?
Yes. Voltage, capacity, dimensions, BMS, connectors, communication interfaces, enclosure, and charging specifications can be customized according to the robot’s requirements.
Can LiFePO4 batteries be used in logistics robots?
Yes. LiFePO4 is a lithium-ion chemistry that can be evaluated for logistics robot applications based on the robot’s electrical and operating requirements.
What voltage is used for logistics robot batteries?
The required voltage depends on the robot’s electrical system. Industrial battery systems may use configurations such as 24V, 36V, 48V, or 51.2V. The correct voltage should be determined from the equipment specifications.
Can a logistics robot battery communicate with the robot controller?
Yes. A smart BMS can support CAN, RS485, UART, or another communication interface when the BMS is configured to match the robot controller.
Can logistics robot batteries support automated charging?
Yes. A battery system can be designed for automated charging when the battery, BMS, charger, and robot controller support the intended charging architecture.
Can the battery dimensions be customized?
Yes. Battery dimensions, enclosure, mounting structure, connectors, cables, and wiring can be customized according to the robot’s installation space.
How do I calculate the required battery capacity?
Start with the robot’s voltage, average power consumption, operating time, peak current, charging schedule, and operating conditions.
The basic energy calculation is:
Wh = V × Ah
Actual battery capacity should be confirmed through the robot’s operating profile.
What certifications are required for logistics robot batteries?
Requirements depend on the battery, application, transportation method, and target market. UN 38.3 is relevant to lithium battery transportation, while additional regional or product-specific requirements may apply.
How long can a logistics robot battery operate?
Operating time depends on battery energy and the robot’s actual power consumption.
A basic estimate is:
Operating Time = Battery Energy ÷ Average Power Consumption
Actual runtime can vary according to payload, driving conditions, motor operation, auxiliary equipment, temperature, and battery operating parameters.
Can the battery support CAN communication and automated charging at the same time?
Yes. A battery can be designed with a smart BMS and CAN communication while supporting an automated charging system, provided the battery, charger, and robot controller are designed with compatible communication and charging requirements.
결론
A Logistics Robot Battery is an integrated power system that needs to work with the robot’s electrical, mechanical, communication, and charging systems.
Battery development should consider:
Cell Chemistry + Voltage + Capacity + Current + BMS + Communication + Charging + Dimensions + Weight + Environment + Safety + Compliance
LiFePO4 is one battery chemistry that can be evaluated for logistics robot applications. Other lithium-ion chemistries may also be considered according to the equipment’s requirements.
For logistics robots, AGVs, AMRs, and warehouse automation systems, a custom lithium battery pack can integrate:
- 배터리 셀
- BMS
- Protection components
- 온도 센서
- CAN 통신
- RS485 통신
- UART 통신
- Custom connectors
- Custom wiring
- 맞춤형 인클로저
A structured OEM/ODM development process can follow:
Requirement Analysis → Cell Selection → Battery Configuration → BMS Design → PACK Design → Prototype → Testing → Validation → Production
For equipment manufacturers, defining battery requirements during the robot development stage can provide the engineering information needed for battery integration and validation.
Dongguan Yizhan Electronics Technology Co., Ltd. provides custom lithium battery PACK solutions for logistics robots, AGVs, AMRs, warehouse robots, and other industrial equipment according to OEM and ODM requirements.