Lithium Battery Pack Design for Industrial Floor Cleaning Machines

Industrial floor cleaning machines are used in warehouses, factories, shopping centers, hospitals, airports, and commercial facilities. These machines rely on electrical power to operate brush motors, vacuum motors, traction systems, controllers, and other components.

Battery-powered floor scrubbers require a battery system designed around the equipment’s electrical load, operating duration, charging arrangement, and installation space.

For manufacturers developing walk-behind floor scrubbers, ride-on cleaning machines, and automated floor cleaning equipment, lithium battery pack design for industrial floor cleaning machines involves electrical, mechanical, and safety considerations.

The battery must provide the required energy and discharge current while remaining compatible with the machine’s controller, charger, electrical connections, and operating environment.

This article explains the technical parameters involved in designing custom lithium battery packs for industrial floor cleaning equipment.

lithium battery pack design for industrial floor cleaning machines

1. Lithium Battery Applications in Industrial Floor Cleaning Equipment

Industrial cleaning machines include several equipment categories with different power and operating requirements.

Walk-Behind Floor Scrubbers

Walk-behind floor scrubbers are operated by personnel and commonly use electrical power for brush rotation, vacuum suction, and traction when equipped with a drive motor.

Battery selection depends on the equipment’s power consumption, operating time, and available battery compartment.

Ride-On Floor Scrubbers

Ride-on floor scrubbers allow operators to control the equipment from a seated position.

These machines may use separate motors for traction, brush operation, and water recovery.

The battery pack must support the combined operating load and the required cleaning schedule.

Industrial Floor Sweepers

Industrial sweepers use brush systems and, depending on the design, vacuum or dust collection equipment.

Battery requirements depend on the brush motors, traction system, dust collection system, and operating conditions.

Autonomous Floor Cleaning Robots

Autonomous cleaning robots combine cleaning equipment with navigation and electronic control systems.

In addition to cleaning motors, the battery may supply power to sensors, onboard computers, communication modules, and navigation equipment.

These applications may require BMS communication, battery status monitoring, and integration with an automatic charging station.

2. Selecting Battery Voltage for Floor Cleaning Machines

Battery voltage is determined by the equipment’s electrical system.

Industrial cleaning machines may use 24V, 36V, or 48V-class electrical architectures, depending on the manufacturer and equipment design.

The actual nominal battery voltage depends on the selected lithium cell chemistry and series configuration.

LiFePO4 Battery Voltage Configurations

LiFePO4 cells typically have a nominal voltage of 3.2V.

Examples of battery configurations include:

구성 공칭 전압 Equipment Voltage Class
8S LiFePO4 25.6V 24V
12S LiFePO4 38.4V Application-dependent
15S LiFePO4 48.0V 48V
16S LiFePO4 51.2V Subject to controller compatibility

These values are illustrative configurations rather than specifications for existing products.

Voltage Compatibility Requirements

Before selecting the battery configuration, the equipment manufacturer should confirm:

  • Nominal system voltage
  • Permitted operating voltage range
  • 최대 배터리 전압
  • Minimum operating voltage
  • Motor controller voltage limits
  • 충전기 사양
  • Battery protection requirements

For example, a 24V-class cleaning machine cannot be assumed to accept every lithium battery marketed as 24V.

The battery’s full charging voltage and discharge cutoff characteristics must be compatible with the equipment.

3. Calculating Battery Capacity for Industrial Floor Scrubbers

Battery capacity should be calculated according to the electrical energy required during the cleaning cycle.

Floor cleaning machines may operate multiple motors simultaneously.

These loads should be included in the capacity calculation.

Electrical Loads in Floor Cleaning Machines

Electrical power may be required for:

  • Brush motors
  • Vacuum motors
  • Traction motors
  • Water pumps
  • Control electronics
  • Display systems
  • 센서
  • Communication modules

The average power consumption depends on how these components operate during a cleaning cycle.

Battery Energy Calculation

Nominal battery energy can be estimated using:

Battery Energy (Wh) = Nominal Voltage (V) × Capacity (Ah)

For example, a theoretical 25.6V 100Ah battery has:

25.6V × 100Ah = 2,560Wh

The value represents nominal battery energy rather than guaranteed usable energy.

Required Energy Calculation

Equipment energy requirements can be estimated using:

Required Energy (Wh) = Average Electrical Power (W) × Operating Time (h)

Example: Walk-Behind Floor Scrubber

Assume a cleaning machine has the following illustrative average electrical loads:

Component Average Power
Brush Motor 300W
Vacuum Motor 250W
Traction Motor 100W
Control and Auxiliary Equipment 20W
Total 670W

For a required operating time of three hours:

670W × 3h = 2,010Wh

The cleaning machine requires approximately 2,010Wh of usable energy under these assumed operating conditions.

If the battery uses a nominal voltage of 25.6V:

2,010Wh ÷ 25.6V = 78.5Ah

This is the theoretical capacity requirement without a usable-energy allowance.

Assuming an illustrative usable energy fraction of 90%:

Required Nominal Capacity = 2,010Wh ÷ (25.6V × 0.90)

Required Nominal Capacity ≈ 87.2Ah

The 90% value is a calculation assumption and should not be treated as a universal battery specification.

The final capacity should account for actual equipment power consumption, battery operating limits, electrical losses, temperature, and aging requirements.

4. Continuous and Peak Discharge Current Requirements

Floor cleaning machines may operate brush, suction, and traction motors simultaneously.

The battery must supply the required current under the specified operating conditions.

연속 방전 전류

Continuous discharge current represents the current required during sustained equipment operation.

An initial current estimate can be calculated using:

Current (A) = Electrical Power (W) ÷ Battery Voltage (V)

For example, assuming an electrical load of 800W and a nominal battery voltage of 25.6V:

800W ÷ 25.6V = 31.25A

This calculation uses nominal voltage and does not represent the current at every battery state of charge.

The battery design should also consider operation at the minimum permitted battery voltage.

피크 방전 전류

Motor startup, traction acceleration, brush engagement, and temporary load changes may create short-duration current demand.

Peak current should be specified with its duration.

An illustrative project may require:

매개변수 Example Requirement
배터리 전압 25.6V
용량 100Ah
연속 방전 전류 40A
피크 방전 전류 80A
Peak Duration 5 seconds

These values are examples for engineering discussion and do not represent verified product specifications.

The actual continuous and peak current requirements must be determined from equipment measurements or the manufacturer’s electrical specifications.

5. LiFePO4 Battery Cell Selection for Cleaning Equipment

Lithium Iron Phosphate (LiFePO4) cells are used in industrial battery applications, including floor cleaning equipment.

Battery cell selection should be based on electrical performance requirements and the available installation space.

Electrical Parameters

Relevant cell specifications include:

  • 공칭 전압
  • 정격 용량
  • 연속 방전 전류
  • Pulse discharge capability
  • 충전 전류
  • 내부 저항
  • 충전 온도 범위
  • Discharging temperature range
  • Cycle life conditions

Mechanical Parameters

The battery designer should also evaluate:

  • 세포 크기
  • Cell weight
  • Terminal structure
  • Cell mounting arrangement
  • 전기 절연
  • Heat dissipation paths

Prismatic and Cylindrical Cells

Prismatic LiFePO4 cells may be used in battery packs requiring specified capacity and enclosure arrangements.

Cylindrical lithium cells may be considered for applications with particular dimensions, current requirements, or mechanical constraints.

The cell format should be selected according to the equipment’s technical specifications.

6. Battery Management System Requirements

The Battery Management System (BMS) is a component of the lithium battery pack.

It monitors battery operating conditions and provides protection functions according to its hardware and software design.

BMS Protection Functions

A floor cleaning machine battery may require:

  • Cell overvoltage protection
  • Cell undervoltage protection
  • 과전류 보호
  • 단락 보호
  • Charging temperature protection
  • Discharging temperature protection
  • 셀 밸런싱
  • 배터리 상태 모니터링

The required functions and protection thresholds should be defined according to the selected cell specifications and equipment requirements.

BMS Current Rating

The BMS must be evaluated against the equipment’s continuous discharge current and defined peak current requirements.

For cleaning machines with multiple motors, simultaneous operation should be considered.

온도 모니터링

Battery temperature sensors can monitor selected locations within the battery pack.

Temperature thresholds should be established according to the selected cells and operating conditions.

State of Charge Monitoring

Some floor cleaning machines display the remaining battery charge.

A BMS may provide State of Charge (SOC) information through a supported interface.

The estimation method and accuracy should be evaluated during system development.

7. CAN Communication for Automated Cleaning Machines

Some industrial floor cleaning machines require communication between the battery and the equipment controller.

Depending on the project, communication options may include CAN, UART, or RS485.

A CAN-equipped BMS can transmit defined battery information according to an agreed communication protocol.

Examples include:

  • 배터리 전압
  • Battery current
  • 충전 상태
  • 온도
  • Protection status
  • 오류 정보

CAN Protocol Integration

The equipment manufacturer should confirm:

  • 통신 인터페이스
  • CAN bit rate
  • Message identifiers
  • 데이터 형식
  • Transmission intervals
  • Connector pin assignments

A CAN interface does not automatically establish communication compatibility between the battery and equipment controller.

Monitoring and Control Functions

For a monitoring-only BMS configuration, CAN communication transmits battery operating data.

Charging and discharging are not automatically controlled through CAN communication.

Any control functions require specific hardware, firmware, and protocol arrangements.

For autonomous floor cleaning robots, communication requirements should be reviewed together with charging station integration.

8. Battery Charging Requirements

Battery charging is part of industrial floor cleaning machine operation.

Depending on the equipment, charging may involve an external charger, onboard charger, or automatic charging station.

충전 전압

Charging voltage must match the selected lithium battery chemistry and series configuration.

The manufacturer should confirm the approved charging profile and voltage limits.

충전 전류

Charging current affects the charging schedule and thermal conditions of the battery.

The selected cells, BMS, connectors, and wiring must support the specified charging current.

Onboard and External Chargers

Some floor cleaning machines include an onboard charger.

Other equipment uses a separate external charger.

Battery and charger compatibility must be evaluated before system integration.

Automatic Charging for Cleaning Robots

Autonomous cleaning equipment may return to a charging station during operation.

The battery design should account for:

  • Charging contact arrangement
  • Charging voltage and current
  • BMS protection behavior
  • Equipment power state during charging
  • Charging station communication, where required

The charging method should be confirmed according to the equipment manufacturer’s system design.

9. Mechanical Design and Battery Compartment Integration

Industrial floor cleaning machines have defined battery installation spaces.

The battery pack must fit the equipment’s mechanical structure and electrical interface requirements.

배터리 크기

Customers should provide the available installation dimensions:

Length × Width × Height

The dimensions should account for the complete battery enclosure, connectors, cable exits, handles, and mounting components.

Battery Mounting

The battery should be secured according to the machine’s operating conditions.

The design should consider vibration, equipment movement, and the specified mounting orientation.

Battery Mass and Machine Stability

Battery mass and its position may influence the machine’s mechanical balance, traction, and stability.

For equipment originally designed around lead-acid batteries, a change in battery mass may require review of the machine’s stability and applicable mechanical requirements.

A lithium battery should not be treated as a direct replacement solely because its nominal voltage and dimensions are similar.

Connectors and Wiring

Battery connections should be selected according to the equipment’s electrical current, mechanical structure, and operating environment.

Connector compatibility, cable specifications, polarity, and installation arrangements should be confirmed during development.

10. Environmental Protection and Operating Conditions

Floor cleaning equipment may operate in environments where water, detergent, humidity, vibration, and temperature changes affect electrical components.

Battery enclosure requirements depend on the equipment’s design and battery installation position.

Water and Moisture Exposure

Battery packs installed near water tanks, cleaning systems, or wet floor areas may require specified protection against moisture.

The required Ingress Protection (IP) rating should be determined according to actual exposure conditions.

Enclosure Materials

Plastic and metal enclosures may be considered according to project requirements.

Material selection should address structural requirements, electrical insulation, environmental exposure, and mechanical integration.

Detergent and Chemical Exposure

Cleaning equipment may use water and chemical detergents.

Where the battery enclosure or connectors may contact these substances, material compatibility should be evaluated.

작동 온도

Battery charging and discharging must follow the selected cell manufacturer’s temperature specifications.

BMS temperature protection and enclosure thermal design should account for the equipment’s working conditions.

11. Lithium Battery Requirements for Walk-Behind and Ride-On Floor Scrubbers

Walk-behind and ride-on cleaning machines may have different electrical and mechanical requirements.

Design Parameter Walk-Behind Floor Scrubber Ride-On Floor Scrubber
Electrical System According to equipment design According to equipment design
Main Loads Brush, vacuum, optional traction Brush, vacuum, traction
배터리 용량 Based on energy demand Based on energy demand
Continuous Current Based on simultaneous loads Based on simultaneous loads
Peak Current Motor startup and load changes Motor startup and load changes
Installation Defined battery compartment Defined battery compartment
BMS Protection and optional monitoring Protection and optional monitoring
충전 Onboard or external Onboard or external
커뮤니케이션 According to controller requirements According to controller requirements

Battery specifications should be determined individually rather than selected solely by machine category.

12. Battery Testing and Applicable Standards

Industrial floor cleaning machine battery development may require electrical, mechanical, environmental, and safety validation.

The required testing depends on the equipment, target market, and applicable product standards.

Electrical Testing

Testing may include:

  • 정격 전압 검증
  • Battery capacity testing
  • Charging and discharging evaluation
  • Continuous current testing
  • 피크 전류 시험
  • BMS protection verification

Mechanical Testing

Testing may include:

  • Battery enclosure inspection
  • Mounting verification
  • Connector assessment
  • 진동 테스트
  • Mechanical integrity assessment

환경 테스트

Depending on the project, testing may include:

  • 온도 시험
  • Humidity exposure
  • Ingress protection testing
  • Exposure to relevant cleaning chemicals

Applicable Standards

Examples of standards and regulatory requirements that may be relevant include:

표준 Scope
IEC 62619 Safety requirements for secondary lithium cells and batteries used in industrial applications
IEC 60335-2-72 Safety requirements for applicable commercial floor treatment machines
IEC 60529 Enclosure ingress protection classification
UN38.3 Transportation testing for lithium cells and batteries
Applicable EU Regulations Product and equipment requirements according to the target market

The applicability of each standard must be evaluated according to the battery design, equipment classification, and market requirements.

Battery-level test results do not automatically establish compliance for the complete floor cleaning machine.

13. Information Required for a Custom Floor Scrubber Battery Quotation

Equipment manufacturers requesting a custom battery pack should provide the following information.

항목 Required Information
Equipment Type Walk-behind scrubber, ride-on scrubber, sweeper, or autonomous cleaner
Nominal Battery Voltage V
Permitted Voltage Range Minimum and maximum voltage
Required Runtime Hours
Average Power Consumption W
연속 방전 전류 A
피크 방전 전류 A and duration
배터리 용량 Ah or Wh, if specified
배터리 화학 LiFePO4 or ternary lithium-ion
배터리 크기 Maximum length × width × height
배터리 무게 Maximum permitted mass or required mass range
BMS Requirements Protection, monitoring, and balancing
커뮤니케이션 CAN, UART, RS485, or other interface
충전 방법 Onboard charger, external charger, or charging station
Charging Voltage and Current V and A
Connector Requirements Charging, discharging, and signal connectors
Enclosure Requirements Material, mounting, and IP rating
작동 온도 Charging and discharging conditions
인증 Applicable standards and target market
Sample Quantity Prototype requirements
Production Quantity Estimated purchase volume
Delivery Destination Country and address

If the required battery capacity has not yet been calculated, customers can provide the equipment’s power consumption and operating duration for an initial technical evaluation.

14. Custom Lithium Battery Packs for Floor Cleaning Machines at Dongguan Yizhan Electronics Technology Co., Ltd.

동관 이잔 전자 기술 유한 공사(동관 이잔 전자 기술 유한 공사) provides OEM and ODM lithium battery pack development and manufacturing services for industrial equipment, electric mobility, robotics, and energy storage applications.

For industrial floor cleaning machine projects, battery configurations can be evaluated according to customer requirements involving electrical load, operating voltage, battery capacity, installation dimensions, and charging interfaces.

Our custom battery pack development services include:

  • LiFePO4 and ternary lithium-ion battery configurations
  • 사용자 지정 전압 및 용량
  • 배터리 셀 선정
  • BMS 구성
  • CAN, UART, and RS485 communication options
  • 온도 모니터링
  • Customized charging and discharging connectors
  • Plastic and metal battery enclosures
  • 배터리 팩 조립
  • Technical documentation and testing coordination

Specific battery configurations, communication functions, environmental requirements, and testing arrangements are determined according to the confirmed project specifications.

We work with equipment manufacturers to evaluate battery requirements for new product development and OEM battery integration.

결론

Lithium battery pack design for industrial floor cleaning machines involves evaluating electrical loads, operating runtime, discharge current, charging requirements, and mechanical installation conditions.

Brush motors, vacuum motors, traction systems, and control electronics determine the equipment’s electrical demand.

Battery voltage, capacity, cell selection, BMS configuration, and charging interfaces must be compatible with the equipment’s electrical architecture.

For walk-behind floor scrubbers, ride-on cleaning machines, and autonomous cleaning equipment, the final battery configuration should be based on confirmed technical requirements and project validation.

Looking for a custom lithium battery pack for industrial floor cleaning equipment?

연락처 동관 이잔 전자 기술 유한 공사(동관 이잔 전자 기술 유한 공사) with your equipment specifications, battery voltage, required runtime, discharge current, battery dimensions, and estimated production quantity.

Our team can review your application requirements and discuss a custom battery pack configuration for your project.

 

Learn about lithium battery pack design for industrial floor cleaning machines, including LiFePO4 cells, voltage, capacity, runtime, BMS, charging and OEM customization.
2026-11-18
+
Dongguan Yizhan supplies EVE LFP battery cells with export documentation support and optional terminal tab processing for international battery pack manufacturers.
2026-11-17
+
Dongguan Yizhan Electronics Technology Co., Ltd. has initiated preparations for the EU Digital Battery Passport, focusing on battery data, traceability and OEM support.
2026-11-16
+
Explore Lithium Batteries for Electric Forklifts and material handling equipment, including LiFePO4 cells, BMS, charging, CAN communication and safety requirements.
2026-11-09
+