Lithium batteries are used in electric forklifts, pallet trucks, stackers, automated guided vehicles (AGVs), and other material handling equipment. These machines rely on battery systems to power traction motors, hydraulic systems, control units, and electrical components.
For equipment manufacturers, selecting a lithium battery involves electrical specifications, mechanical integration, charging requirements, and operating conditions.
Lithium batteries for electric forklifts and material handling equipment must be evaluated according to the vehicle’s voltage, capacity, discharge current, battery compartment, and operating cycle.
Battery Management System (BMS) functions, charging interfaces, communication requirements, and applicable safety standards are also part of the development process.
This article explains the technical considerations involved in lithium battery selection and custom battery pack development for electric forklifts and industrial material handling applications.

1. Lithium Battery Applications in Material Handling Equipment
Material handling equipment is used in warehouses, manufacturing facilities, distribution centers, and logistics operations.
Different equipment types have different electrical and mechanical requirements.
一般的な用途は以下の通り:
電動フォークリフト
Electric forklifts use battery systems to supply power for vehicle movement, lifting, and other electrical functions.
Battery requirements depend on the forklift model, rated load, motor controller, hydraulic system, and operating conditions.
Electric Pallet Trucks
Electric pallet trucks are used to transport goods over warehouse floors.
Battery specifications depend on the equipment’s motor power, operating cycle, charging method, and installation space.
Electric Stackers
Electric stackers use battery power for traction and lifting functions.
Battery design should consider the current required during movement and lifting operations.
リーチトラック
Reach trucks are used in warehouse storage and material handling applications.
Battery selection should follow the vehicle manufacturer’s electrical and mechanical specifications.
AGVとAMR
Automated Guided Vehicles (AGVs) and Autonomous Mobile Robots (AMRs) are used in automated material handling systems.
Their battery packs may require customized dimensions, BMS functions, and communication interfaces.
Each equipment application requires evaluation of the battery voltage, current, capacity, enclosure structure, and charging requirements.
2. Selecting Battery Voltage for Electric Forklifts
Battery voltage is a basic parameter in industrial battery design.
The required voltage depends on the vehicle’s motor controller, drive system, electrical components, and charging system.
Voltage classes encountered in material handling equipment include:
- 24V
- 36V
- 48V
- 80V
The actual battery voltage depends on the selected chemistry and series cell configuration.
LiFePO4 Battery Configurations
LiFePO4 battery cells have a typical nominal voltage of 3.2V per cell.
Examples of series configurations include:
| LiFePO4 Configuration | 公称電圧 | Equipment Voltage Class |
|---|---|---|
| 8S | 25.6V | 24V class |
| 12S | 38.4V | Application-dependent |
| 15S | 48.0V | 48V class |
| 16S | 51.2V | 48V class, subject to compatibility |
| 25S | 80.0V | 80V class |
These configurations are calculation examples. They do not represent specific products of Dongguan Yizhan Electronics Technology Co., Ltd.
Equipment voltage classes do not establish the permitted battery operating voltage range.
Before selecting a battery configuration, the forklift manufacturer should confirm:
- 公称系統電圧
- Motor controller operating voltage range
- Maximum allowable battery voltage
- 最小動作電圧
- Charging voltage requirements
- Compatibility with the existing electrical system
A battery pack should not be selected based only on a nominal voltage label.
3. Battery Capacity and Operating Time
Battery capacity determines the amount of electrical charge available under specified operating conditions.
Capacity is expressed in ampere-hours (Ah), while battery energy is expressed in watt-hours (Wh) or kilowatt-hours (kWh).
バッテリーのエネルギー計算
Nominal battery energy can be calculated using:
Energy (Wh) = Nominal Voltage (V) × Capacity (Ah)
For example, a theoretical LiFePO4 battery pack with:
- 公称電圧:51.2V
- Capacity: 200Ah
Has a nominal energy of:
51.2V × 200Ah = 10,240Wh = 10.24kWh
This example is for calculation purposes and does not represent an existing product of Dongguan Yizhan Electronics Technology Co., Ltd.
Factors Affecting Battery Capacity Selection
Required battery capacity depends on:
- 機器の消費電力
- 営業時間
- 積載重量
- 移動距離
- リフトの頻度
- Acceleration and braking cycles
- Charging intervals
- 周囲温度
- Equipment standby consumption
For forklift projects, customers should provide the vehicle’s electrical specifications and operating duty cycle.
Battery capacity should be evaluated according to the expected energy consumption and required operating time.
4. Continuous and Peak Discharge Current Requirements
Electric forklifts and industrial handling equipment may draw different currents during normal travel, motor startup, and lifting operations.
Continuous discharge current and peak discharge current should be defined separately.
連続放電電流
Continuous discharge current refers to the current required during sustained operation.
This parameter affects:
- 電池セルの選定
- BMS current rating
- Busbar design
- Power cable selection
- コネクタの仕様
- 熱管理
ピーク放電電流
Peak discharge current refers to a short-duration current demand.
Current pulses may occur during:
- Vehicle acceleration
- モーターの起動
- Hydraulic lifting
- Movement under load
- Changes in operating conditions
For example, a proposed battery specification may require:
| パラメータ | Illustrative Requirement |
|---|---|
| 公称電圧 | 51.2V |
| 定員 | 200Ah |
| 連続放電電流 | 100A |
| ピーク放電電流 | 200A |
| Peak Current Duration | 5 seconds |
These values are illustrative engineering requirements, not verified production battery specifications.
The peak current duration and repetition frequency should be confirmed during technical evaluation.
The selected battery cells, BMS, electrical connections, and connectors must be evaluated according to the complete current profile.
5. LiFePO4 Battery Cell Selection for Forklift Applications
Lithium Iron Phosphate (LiFePO4) is a battery chemistry used in industrial traction and material handling applications.
Cell selection depends on the required electrical specifications, battery dimensions, operating temperature, and equipment requirements.
プリズム型LiFePO4セル
Prismatic cells are used in industrial battery modules and energy storage systems.
Their rectangular structure allows engineers to design battery arrangements according to the available enclosure dimensions.
細胞の選定にあたっては、以下の点を考慮すべきである:
- 公称容量
- 連続放電電流
- Pulse current capability
- 内部抵抗
- Cycle life specifications
- 動作温度
- 細胞の寸法
- Terminal structure
- Manufacturer documentation
Series and Parallel Configuration
Battery cells are connected in series and parallel to obtain the required voltage and capacity.
Series connections determine the pack voltage.
Parallel connections determine the combined capacity and contribute to the pack’s current capability.
The configuration must also account for the available installation space, electrical connections, insulation, and thermal conditions.
Cell Manufacturer Requirements
If a forklift project specifies a particular cell manufacturer or model, the requirement should be included in the technical documentation.
The final cell configuration should be evaluated according to the manufacturer specifications and the equipment’s electrical load.
6. Battery Management System Requirements
The Battery Management System (BMS) monitors battery conditions and provides protection functions according to its hardware and firmware configuration.
For forklift and material handling battery packs, BMS requirements should be defined during the design stage.
Electrical Protection Functions
Depending on the design, BMS functions may include:
- 過充電保護
- 過放電保護
- 過電流保護
- 短絡保護
- 温度保護
- 細胞電位のモニタリング
- セルバランシング
Current Monitoring
The BMS may monitor charging and discharging current according to its measurement system.
The continuous current rating and peak current requirements should be evaluated alongside the selected electrical protection components.
温度モニタリング
Temperature sensors may be installed at defined locations within the battery pack.
Monitoring positions can include selected cells, electrical connections, and BMS components.
The number and location of sensors depend on the battery configuration and thermal design.
SOC and SOH Reporting
Depending on the BMS configuration, battery information may include:
- 充電状態(SOC)
- 健康状態(SOH)
- バッテリー電圧
- バッテリー電流
- バッテリー温度
- 障害状況
The availability of these functions should be confirmed according to the selected BMS hardware and firmware.
7. CAN Communication for Electric Forklift Batteries
Some industrial vehicles and material handling systems require battery information to be transmitted to the equipment controller.
CAN communication may be used for this purpose.
A CAN-enabled BMS can transmit defined battery information according to an agreed communication protocol.
The transmitted information may include:
- バッテリー電圧
- バッテリー電流
- SOC
- バッテリー温度
- 保護状況
- 障害情報
CAN Protocol Requirements
For battery projects requiring CAN communication, customers should provide:
- CAN bit rate
- CAN identifiers
- Message format
- Data definitions
- Transmission intervals
- Connector pin assignments
- Required status information
CAN Monitoring and Control
CAN communication does not automatically provide control over battery charging or discharging.
In a monitoring-only configuration, CAN transmits battery information to the equipment controller.
Charging and discharging functions depend on the BMS electrical design and connected equipment.
If the project requires CAN-based control functions, these requirements must be defined and evaluated separately.
8. Charging Systems for Forklift Lithium Batteries
Battery charging is part of the equipment’s operating system.
The required charger specifications depend on the selected battery cells, battery configuration, BMS, and vehicle design.
充電電圧
The charger output voltage must be compatible with the battery’s charging voltage requirements.
充電電流
Charging current should be selected according to the cell manufacturer specifications and battery pack design.
Charging Connectors
Charging connector selection should consider:
- 定格電圧
- 定格電流
- Connector structure
- ケーブルの仕様
- 設置位置
- 機械的保護
- 環境条件
Charger Communication
Some charging systems use communication between the battery, charger, and equipment controller.
The communication protocol and charging current control responsibilities should be defined during system integration.
Charging Operation
Equipment manufacturers should confirm whether the forklift uses:
- Manual charging
- Battery removal for charging
- Onboard charging
- Dedicated charging stations
- Scheduled charging during operating breaks
The charging arrangement affects the electrical interface, mechanical structure, and project requirements.
9. Mechanical Design and Battery Compartment Requirements
The battery pack must fit within the equipment’s designated installation compartment.
For custom forklift lithium battery packs, mechanical requirements may include:
- Battery length
- Battery width
- Battery height
- バッテリー重量
- Mounting positions
- Cable outlet positions
- Connector locations
- Enclosure material
- 保守用アクセス
Battery Enclosure
Industrial battery enclosures may use metal structures designed according to the mechanical requirements.
The enclosure should account for:
- Cell mounting
- 電気絶縁
- Mechanical support
- Vibration conditions
- Connector protection
- 放熱
- Installation and removal procedures
Battery Weight and Forklift Stability
Battery weight requires specific attention in forklift applications.
For certain electric forklifts, battery mass contributes to the vehicle’s stability and counterweight arrangement.
A lithium battery pack should not be treated as a direct replacement for an existing battery based only on voltage, capacity, and compartment dimensions.
When replacing or modifying a battery system, the equipment manufacturer should confirm:
- Permitted battery weight range
- Battery compartment requirements
- Vehicle stability requirements
- Counterweight arrangement
- Mounting and retention requirements
- Approval requirements for changes to the vehicle
Battery weight and vehicle modifications must follow the equipment manufacturer’s instructions and applicable safety requirements.
10. Thermal Management and Operating Conditions
Forklift batteries generate heat during charging and discharging.
Thermal behavior depends on the battery cell model, current, electrical resistance, operating temperature, and enclosure design.
Thermal considerations include:
- 連続放電電流
- ピーク電流の持続時間
- 充電電流
- 細胞の配列
- BMS温度
- Enclosure material
- 周囲温度
- 放熱
動作温度
Customers should provide the specified operating temperature range.
For example, forklifts operating in refrigerated warehouses may require evaluation of battery discharge performance and charging temperature restrictions.
Charging and discharging temperature limits should be considered separately.
防塵・防水
Material handling equipment may operate in warehouses or industrial environments involving dust and moisture.
If an ingress protection rating is required, the complete battery enclosure should be evaluated according to the specified IP classification.
The required rating depends on the installation environment and equipment requirements.
11. Battery Safety Standards and Testing Requirements
Battery testing and certification requirements depend on the application, destination market, and product classification.
The following standards may be relevant during project evaluation.
| スタンダード | Application or Purpose |
|---|---|
| IEC 62619 | Safety requirements for secondary lithium cells and batteries used in industrial applications |
| UN38.3 | Lithium battery transportation testing |
| IEC 60529 | Degrees of protection provided by enclosures |
| UL 2580 | Safety evaluation of batteries for electric vehicles, where applicable |
The applicable standards should be confirmed according to the battery product and target market.
Electrical Validation
Electrical testing may include:
- Voltage inspection
- キャパシティ検証
- 充放電試験
- Continuous current evaluation
- ピーク電流試験
- BMS protection verification
Mechanical Validation
Depending on the application, mechanical validation may include:
- Dimensional inspection
- Enclosure inspection
- Mounting verification
- 振動試験
- コネクタ検査
Thermal Validation
Thermal evaluation may include:
- 温度上昇試験
- Operating temperature evaluation
- Temperature sensor verification
- BMS temperature protection testing
The testing scope and acceptance criteria should follow the approved project requirements.
Engineering validation does not automatically establish formal product certification.
12. Information Required for a Custom Forklift Battery Quotation
When requesting a custom lithium battery pack for a forklift or material handling application, customers should provide the following information.
| 項目 | Required Information |
|---|---|
| Equipment Type | Forklift, pallet truck, stacker, reach truck, AGV or other equipment |
| Equipment Manufacturer | Brand and model |
| 公称電圧 | 必要電圧 |
| バッテリー容量 | 「あ」か「う」か |
| 連続放電電流 | A |
| ピーク放電電流 | A and duration |
| バッテリー化学 | LiFePO4 or specified chemistry |
| バッテリー寸法 | 長さ × 幅 × 高さ |
| バッテリー重量 | Required or permitted weight range |
| BMS Requirements | Protection and monitoring functions |
| コミュニケーション | CAN, UART, RS485 or other interface |
| 充電 | Voltage, current and charger specifications |
| コネクタ | Charging, discharging and communication interfaces |
| 動作温度 | Charging and discharging temperature ranges |
| 環境要件 | Dust, moisture and vibration |
| 認証 | Applicable standards and target market |
| Prototype Quantity | Required sample quantity |
| Production Quantity | Initial order and estimated annual demand |
| Delivery Destination | Country and address |
For forklift applications, customers should also provide the vehicle manufacturer’s battery installation specifications and applicable approval requirements.
These details are used to evaluate the battery configuration, mechanical design, electrical components, and project scope.
13. Custom Industrial Lithium Battery Packs at Dongguan Yizhan Electronics Technology Co., Ltd.
東莞伊湛電子科技有限公司 provides OEM and ODM custom lithium battery pack development and manufacturing services for electric mobility, robotics, industrial equipment, and energy storage applications.
Our customization scope includes:
- LiFePO4 and ternary lithium-ion battery configurations
- Customized battery voltage and capacity
- 電池セルの選定
- BMS configuration according to project requirements
- CAN, UART, and RS485 communication options
- NTC temperature monitoring
- Customized connectors and wiring
- Plastic and metal battery enclosures
- バッテリーパックアセンブリ
- Technical documentation and project testing coordination
For material handling battery projects, electrical specifications, installation dimensions, operating current, communication interfaces, and environmental requirements are considered during technical evaluation.
Forklift-specific battery requirements, including battery weight, vehicle compatibility, and relevant safety requirements, must be confirmed according to the equipment manufacturer’s specifications.
The battery configuration and manufacturing scope are determined according to the confirmed project requirements.
結論
Lithium batteries are used in electric forklifts and material handling equipment with defined electrical, mechanical, and operating requirements.
Battery selection involves voltage, capacity, continuous and peak discharge current, BMS protection, charging systems, connectors, and enclosure design.
For forklift applications, battery weight and vehicle stability must also be considered during battery selection or replacement projects.
OEM and ODM customers should provide equipment specifications, battery compartment dimensions, electrical requirements, and production quantities during the quotation stage.
Looking for a custom lithium battery pack for material handling equipment?
連絡先 東莞伊湛電子科技有限公司 with your equipment model, battery voltage, capacity, discharge current, installation dimensions, BMS requirements, and estimated order quantity.
Our team can review the project specifications and discuss a battery configuration based on the equipment requirements.